Product Basic Introduction
PD-0770 is a single-plate parallel clevis under PD series power fittings. It can be assembled in single-to-single or single-to-double plate combinations to match various insulator string layouts. When combined with other standard line hardware, it meets connection requirements for medium voltage distribution and high-voltage transmission lines over 110kV. The slim, compact body fits narrow installation spaces on tower crossarms and substation racks
The unified PD series naming rule simplifies engineering selection, and we provide multiple optional surface treatments to adapt to inland, coastal and industrial polluted environments. It is widely stocked by global power hardware distributors for 10kV distribution and matching assembly of 110kV+ high-voltage lines
Factors That Decide Anti-Corrosion Performance
Many overseas clients ask why identical PD-0770 clevis show different rust resistance in different regions. The main influencing factors are summarized below:
Base Material and Processing State
Q235B steel itself has limited natural rust resistance and fully relies on surface zinc coating for protection. Stamping and forging may create local stress concentration zones, lowering electrode potential and triggering spot corrosion if the galvanizing layer has tiny gaps;
Ambient Corrosive Substances
Coastal areas contain abundant chloride ions that penetrate the zinc oxide protective film and consume the zinc layer rapidly. Industrial zones release sulfur dioxide and nitrogen oxides, which form acid rain and accelerate coating aging;
Long-Term Humidity
Constant damp air keeps the clevis surface moist, creating a persistent electrolytic environment that speeds up both zinc layer loss and substrate corrosion
Optional Surface Treatment Solutions (Besides Standard Hot-Dip Galvanizing)
We offer extra surface finishing upgrades for projects with strict anti-rust standards:
Passivation Treatment Applied after galvanizing, it forms a dense passive film on the zinc surface. Boosts salt spray resistance and strengthens bonding between the zinc layer and substrate;
Phosphating Treatment Creates a stable phosphate conversion film. It delivers mild anti-corrosion performance and serves as an ideal primer if clients need to apply extra anti-rust paint on site;
Black Oxidation (Bluing) Forms a 0.5–1.5 μm Fe₃O₄ protective film on steel without thick zinc layers. Relieves residual stamping stress and minimizes plate deformation during long-term service
Standard Step-by-Step Installation Guide
Align the clevis mounting holes perfectly with the holes on matched insulator clamps or hanging plates to avoid offset assembly. Misalignment will generate eccentric load and cause hole wall deformation;
Install high-strength bolts with bolt heads facing away from the main tension direction; leave 2–3 complete screw threads exposed beyond the nut for reliable locking;
Tighten bolts in two stages with a torque wrench. One-step over-tightening will bend the thin 7mm plate and damage the galvanized coating.
Complete visual and load inspection after assembly before putting the line into operation
Routine Maintenance Tips for Corrosive Working Zones
If PD-0770 clevis are deployed in coastal, chemical or acid rain areas:
Clean surface dirt and re-coat zinc-rich anti-rust paint every 2–3 years;
Timely touch up any scratched zinc layer to block corrosive media from reaching the steel substrate;
Regular maintenance extends the fitting's service life and eliminates hidden safety hazards for power lines
Hot Tags: pd-0770 clevis, China pd-0770 clevis manufacturers, suppliers, factory, PS Clevis, PD 0770 Clevis, PD 1080 type Clevis, P type Clevis, UB 12 type Clevis, Z 42150 type Clevis