L-16-100/600 Yoke Plate

Send Inquiry
L-16-100/600 Yoke Plate
Details
Our L-1640 L-type yoke plate, marked with the full model L-16-100/400, is a standard heavy-duty connection fitting widely matched with our full range of power hardware including adjusting plates, triangular yoke plates and square connecting plates for complete overhead line matching. Each number in the model code carries clear engineering meaning: “16” stands for a minimum rated breaking load of 160kN, “100” refers to the effective connecting length of the plate body, and “400” indicates compatibility with conductors with a cross-section of 400mm².
Category
Yoke Plate
Share to
Description

Our L-1640 L-type yoke plate marked L-16-100/400 is a standard heavy-load connecting fitting engineered for 220kV and higher overhead power transmission lines, matching our full range of power fittings including adjusting plates, triangle yoke plates and square connection plates for complete line matching. Each digit in the model code carries clear engineering reference: "16" corresponds to a nominal breaking load of 160kN, "100" stands for the main connection length of the plate body, and "400" means it fits conductors with 400mm² cross-sectional area.

This yoke plate features overall outer dimensions of 400mm × 160mm, with a 16mm thick carbon steel plate as raw material. Its structural parameters include 100mm plate width, two sets of hole pitches at 26mm and 20mm, and 18mm standard mounting holes. The finished product weighs roughly 5.8–5.9kg, with a core assembly hole of 26mm to match standard power bolts. We adopt premium carbon steel sheets for production and apply full hot-dip galvanizing treatment, with zinc coating thickness controlled above 86μm. The dense zinc layer delivers outstanding anti-rust and anti-corrosion performance, allowing stable long-term operation in all kinds of open-air power grid environments.

As a vital load-bearing connector on overhead lines, this hardware links insulator strings, suspension clamps and other power fittings together. It transfers mechanical tension and electrical load evenly across the whole assembly, forming a stable connection system for power transmission. Its unique five-hole layout brings great flexibility for adjusting split spacing of double-split and multi-split conductors. Boasting a rated breaking load of 160kN, it can cope with harsh working conditions such as wind-prone zones and heavy ice-covered areas. Widely deployed on tension strings of angle towers, it effectively disperses lateral stress brought by conductor turning and avoids deflection or offset of insulator strings. Mixed-size mounting holes support bolts of different specifications, enabling matched assembly with various standard line fittings, making it a versatile choice for long-span projects with double-split conductors.

During long-term outdoor service, improper operation or severe environment may trigger common abnormal conditions:

Overload rupture: If the actual working load exceeds the rated 160kN, cracks or tearing will emerge on the plate body and around bolt holes;

Fatigue cracking: Recurring alternating loads induce metal fatigue, creating radial cracks along bolt hole edges;

Corrosion failure: Sand abrasion and long-term weathering wear away the galvanized layer, lowering the fitting's tensile capacity;

Seized bolts: Small-diameter bolts tend to rust solid, requiring dedicated release agents for disassembly;

Insulator string falling: Loose cotter pins lead to insulator string deviation and detachment, disrupting normal line operation.

Any abnormal issue must be rectified immediately to prevent further line safety hazards.

If maintenance or replacement of the L-1640 yoke plate is needed, follow standardized safe disassembly procedures:

Cut off power supply: Notify local power operation department, isolate the circuit and cut power with professional insulating tools;

Dismount bolts in sequence: Loosen fasteners with wrenches; for double-conductor layouts, remove auxiliary hole bolts first before handling main connection holes;

Separate insulator strings: Secure insulators with special fixtures, then take out cotter pins for bowl hangers and U-rings one by one;

Remove the yoke plate: After all connecting components are fully detached, slide the plate out from its installation position steadily.

We are a professional manufacturer offering a complete series of standard yoke plates and custom power hardware. Our factory strictly implements mechanical load testing and coating inspection for every batch to guarantee stable product quality. Whether you have questions about model selection, on-site installation or fault handling of the L-1640 yoke plate, our technical sales team can provide tailored support and solutions for your transmission line projects

Hot Tags: L-16-100/600 Yoke Plate, China L-16-100/600 Yoke Plate manufacturers, suppliers, factory, LS 1212 Yoke Plate, L 1240 type yoke plate, LF 3040 Yoke Plate, LS type yoke plate, LF 2140 Yoke Plate, LV 1020 Yoke Plate